DETCON > PROCESS ANALYZERS

Detcon Model series 1000-H2S
process analyzers provide continuous, real-time
measurement of H2S concentrations in natural gas pipelines,
tail gas lines, SRU overhead gas lines, as well as other
applications. Available ranges are from 0-10 ppm up
to 0-10%. Other ranges are available on request. The
system can be provided with on-board manual calibration.
The design employs Detcon’s proprietary solid
state MOS sensor element with a ten-year conditional
warranty. The analyzer features a microprocessor-based
signal-conditioning transmitter with local digital display,
fault supervision, calibration mode indicator, alarm
relays and an RS-485 serial port. The instrument package
is rated for use in electrically classified areas: Class
I; Division 1; Groups C, and D. Line power, battery
and solar powered models are available.

Detcon Model 1000-CO2 process analyzers
provide continuous, real-time measurement of CO2 concentrations
in natural gas pipelines, gas treating plants, SRU overhead
gas lines, as well as other applications. Available
ranges are from 0-3,000 ppm up to 0-100%. The system
can be provided with optional on-board manual calibration.
This design employs Detcon’s sub-miniature NDIR
optical sensor element with a five-year conditional
warranty. The analyzer features a microprocessor-based
signal conditioning transmitter with local digital display,
fault supervision, calibration mode indicator, alarm
relays and an RS-485 serial port. The instrument package
is rated for use in electrically classified areas: Class
I; Division 1; Groups C, and D. Line power, battery
and solar powered models are available. 0-5% CO2 Range
Shown with Sample Flow Fault Option
Detcon Model 1000-H2S/CO2
dual process analyzers provide simultaneous and continuous
measurement of both H2S and CO2 concentrations. Available
ranges for H2S are from 0-10 ppm up to 0-10% volume.
Available ranges for CO2 are from 0-0.3% up to 0-100%.
CO2 detection is made using Detcon’s sub-miniature
NDIR optical sensor element with a five-year conditional
warranty. H2S detection is made using Detcon’s
proprietary solid-state MOS H2S sensor element with
a 10-year conditional warranty. The analyzer features
microprocessor-based signal-conditioning transmitters
with local digital display, fault supervision, calibration
mode indicator, alarm relays and an RS-485 serial port.
The instrument package is rated for use in electrically
classified areas: Class I; Division 1; Groups C, and
D. Line power, battery and solar powered models are
available.

Portable H2S Analyzer
The Detcon Model P-1000-H2S is a portable gas analyzer
designed to provide accurate measurement of Hydrogen
Sulfide gas concentrations in natural gas wells, natural
gas pipelines and in the outlet from natural gas treating
plants. The portable battery powered instrument utilizes
advanced electrochemical sensor technology and microprocessor
based electronic control circuitry that includes a built-in
portable data logger. Stored data can be downloaded
to a spreadsheet and used to create trend graphs, average
readings and peak values. A universal signal conditioning
circuit with an LCD display and any one of three intelligent
sensor modules can be combined to provide ranges of
measurement of 0-20 PPM, 0-100 PPM or 0-1000PPM. The
analyzer sensor and control circuitry are mounted in
a weatherproof enclosure with a built-in battery supply
and secondary sample conditioning components. The Model
P-1000-H2S is capable of continuous operation for a
period of approximately 30 days before battery recharge
is required. The intrinsically safe design is suitable
for hazardous area usage. Electrical Class: Class I;
Div1; EEx ia IIC T3C
Enclosure Class: NEMA 4X, IP 66